The month of July has the highest historical solar radition values in West Reading with an average of 5.86 kWh/m2/day. [More]
Solar Panels in West Reading
Solar panels in West Reading that are tilted towards the equator at an angle equal to the latitude will produce the maximum solar energy output. [More]
Sunrise & Sunset in West Reading
The total length of the day in West Reading, PA today (December 22, 2024) will be 9 hours and 21 minutes. [More]
Solar Power in West Reading, PA
Solar Energy Data in West Reading, PA
See the chart below to see how different types of solar panel installations compare in West Reading.
Based on historical West Reading, PA data, solar panels that are tilted towards the equator at an angle equal to the latitude will produce the maximum solar energy output in West Reading.[1]
West Reading has an average monthly Global Horizontal Irradiance (GHI) of 3.94 kilowatt hours per square meter per day (kWh/m2/day), which is approximately 4% greater than the average monthly Direct Normal Irradiance (DNI) of 3.8 kWh/m2/day. [1]
Solar installations in West Reading that are always titled at the latitude of West Reading (Average Tilt at Latitude or ATaL) average 4.6 kWh/m2/day, or about 17% greater than the average monthly GHI of 3.94 kWh/m2/day and approximately 21% greater than the average monthly DNI of 3.8 kWh/m2/day. [1]
Solar Energy Glossary
Global Horizontal Irradiance (GHI)
Global Horizontal Irradiance: The total amount of solar radiation that is received per unit area by a surface that is always positioned in a horizontal manner.
Direct Normal Irradiance (DNI)
Direct Normal Irradiance: The total amount of solar radiation received per unit area by a surface that is always perpendicular to the sun rays that come in a straight line from the direction of the sun at its current position in the sky.
Average Tilt at Latitude (ATaL)
Average Tilt at Latitude: The total amount of solar radiation received per unit area by a surface that is tilted toward the equator at an angle equal to the current latitude. ATaL will often produce the optimum energy output.
Solar Radiation Levels in West Reading
Solar Radiation Data in West Reading, PA
See the chart below for monthly solar radiation levels in West Reading.
* Amounts listed in kWh/m2/day (kilowatt hours per square meter per day)
Solar Radiation Analysis for West Reading, PA
West Reading, PA has a average annual solar radiation value of 4.77 kilowatt hours per square meter per day (kWh/m2/day). [1]
The month with the highest historical solar radition values in West Reading is July with an average of 5.86 kWh/m2/day, followed by August at 5.67 kWh/m2/day and April at 5.52 kWh/m2/day. [1]
The three months that historically average the lowest average solar radiation levels in West Reading (Pennsylvania) are December with an average of 3.04 kWh/m2/day, followed by January with an average of 3.61 kWh/m2/day and November at 3.67 kWh/m2/day. [1]
Solar Power Comparison: West Reading vs. the U.S.
Solar Power Levels in West Reading
The average monthly solar radiation level in West Reading, PA, of 4.77 kilowatt hours per square meter per day (kWh/m2/day) is approximately 21% greater than the average level of 3.93 kWh/m2/day in a city with historically low levels (WA) and is approximately 28% less than the average level of 6.61 kWh/m2/day in a city with historically high levels (NV). [1]
→ Values listed as 0 (zero) are not available (N/A).
Solar Power: West Reading vs. the U.S.
Below is a month-by-month comparison of how average West Reading solar radiation levels compare to average levels in a city with historcially high levels (NV) and a city with historically low levels (WA). [1]
→ k/m/d = kWh/m2/day = kilowatt hours per square meter per day.
→ Values listed as 0 (zero) are not available (N/A).
We do not currently have data on solar panel installations in the borough of West Reading, PA at this current time.
Solar Power Output in West Reading
The Power of Solar in West Reading, PA
Monthly AC solar system output averages for West Reading (pa). Month-by-month solar power, as ranked by AC output, in West Reading. [2]
* Amounts listed in kWhac (kilowatt hours (AC))
Solar Output Analysis for West Reading, PA
West Reading (PA) has a average annual solar AC output value of 5271.3 kilowatt hours (AC). [2]
The month with the highest historical solar power output in West Reading is July with an average of 525.49 kWhac, followed by August at 509.63 kWhac and April at 502.37 kWhac. [2]
The three months that historically average the lowest average solar output levels in West Reading (Pennsylvania) are December with an average of 303.56 kWhac, followed by November with an average of 342.22 kWhac and January at 363.1 kWhac. [2]
Cost of Utilities in West Reading
West Reading Electricity Costs
Sorry, West Reading residential electricity prices are currently unavailable.
Please check back later.
Solar Power Poll: West Reading
Vote now: Given all of the data and analysis provided for West Reading, is solar power a good choice for residents of this borough?
West Reading Natural Gas Costs
Sorry, Pennsylvania residential natural gas prices are currently unavailable.
The borough of West Reading, PA in Berks County has an approximate population of 4,212. [6]
West Reading, PA Solar Energy
To learn more about solar energy and solar power West Reading, PA, or for more solar-related resources for West Reading, visit the U.S. Energy Information Administration.
Did you know?
Solar power is renewable, does not produce any pollutants and is one of the cleanest source of energy.